Renovimo
A steel ship's ladder with handrails both sides climbing to a hatch in the ceiling of a tower room

Engineering calculator

Ship ladder calculator

A ship's ladder is a stair steep enough to climb facing it, with real treads instead of rungs — ship ladder stairs, in a loft or a boat. The IRC lets its treads be as little as 5 in apart, nosing to nosing, with risers up to 9½ in and a handrail on both sides. A 9 ft rise at 60° takes 12 risers of 9 in and 11 treads 5 3/16 in apart, and runs 4 ft 9 3/16 in where a straight stair needs 11 ft 8 in. Enter yours, or switch to an alternating tread stair, for the layout, the stringers and the ladder in 3D.

Enter your rise

Ladder or alternating tread stair

A ship's ladder has full-width treads between two stringers. An alternating tread stair has half treads, left and right in turn, one for each foot, so each foot gets a deeper tread to stand on. Measure the rise from the finished lower floor to the finished upper floor.

Width and lumber

A wooden ship's ladder with a black steel handrail climbing to a loft under a pine ceiling

Based on your result

What you'll need

Lay out one stringer from the drawing, cut the dados, then use it as the pattern for the other — on an alternating stair, the mirror image with the other half of the treads. Glue and screw the treads in, stand the ladder against the header and fix both ends before the handrails go on.

Stringers
Uncut boards, dadoed for the treads
Calculate above
Treads
Full width, or half treads in turn
Calculate above
Structural screws, 3 in Amazon
Through each stringer into every tread end
Calculate above
Top and foot fixings Amazon
Angle brackets into the header and the floor
Calculate above
Handrails Amazon
Both sides, 30–34 in above the nosings
Calculate above
Handrail brackets Amazon
Near each end and about every 4 ft
Calculate above

As an Amazon Associate I earn from qualifying purchases.

The maths

How this ship ladder calculator works

A steep stair is laid out from its angle: the riser sets the height of each step, and the angle sets how far forward the next tread is. Because the treads overlap, the board is deeper than the step, and what hangs in front is the nosing.

risers = round(rise ÷ target), +1 while a riser > 9½ in
treads = risers − 1 (the upper floor is the top step)
going = riser ÷ tan(angle), nosing to nosing
nosing = tread board depth − going
run = treads × going
tread spacing on the stringer = riser ÷ sin(angle)
  1. 01

    Divide the rise

    The total rise over the riser you would like, rounded to whole steps, with one more step while a riser is over 9½ in. A 9 ft rise at 9 in takes 12 risers: 11 treads and the upper floor.

  2. 02

    Set the angle

    The IRC sets no angle for a ship's ladder, and 50–70° for an alternating tread stair, but both need 5 in between adjacent nosings: with 9 in risers neither can be steeper than about 61°, and 62.2° even at the 9½ in limit.

  3. 03

    Check the tread

    The tread plus its nosing must be at least 8½ in deep: a 2 × 10, at 9¼ in, does it at any angle; a 2 × 8 is too shallow. On an alternating stair each half tread must be at least 7 in wide.

  4. 04

    Fix both ends

    The stringers stand on the floor with a level cut and bear against the header with a plumb cut, each end fastened with an angle bracket. A steep ladder is pushed and pulled sideways as you climb, so the fixings matter more than on a stair.

  5. 05

    Rails on both sides

    Both types need a handrail each side, 30 to 34 in above the nosings, with at least 20 in clear between them. On a steep stair the rails are what you hold all the way up.

Good to know

Ship ladder code, angle and dimensions, and alternating tread stairs

IRC 2021 R311.7.12: treads at least 5 in deep, nosing to nosing; the tread plus its nosing at least 8½ in; risers no more than 9½ in; handrails on both sides, 30 to 34 in above the nosings, with at least 20 in clear between them. It is not a means of egress on its own, except as the only way up to a small loft (see below).

The IRC sets no angle for a ship's ladder, but its tread rule does: with 5 in between nosings and risers of 9½ in at most, it cannot be steeper than 62.2°, and with 9 in risers about 61°. Most are built between 55 and 60°. Anything steeper is a ladder, not a stair.

An alternating tread stair: half-width treads, left and right in turn, so each foot has its own tread (R311.7.11). Each half tread must be at least 7 in wide, 5 in deep nosing to nosing from the one beside it and 8½ in deep with its projection, with risers no more than 9½ in, 20 in clear between the handrails and an angle of 50 to 70°. With 5 in treads and 9½ in risers the IRC version cannot actually pass 62.2°; the 70° figure comes from industrial stairs.

As a second way up, anywhere. As the only way up, since the 2018 IRC (and in 2021), only to a loft, mezzanine or similar area of 200 sq ft or less that is not the only way to a kitchen or bathroom. A bedroom over that size needs a code stair. The same rules apply to an alternating tread stair; check which edition your area has adopted.

For a 9 ft rise at 60°: 4 ft 9 3/16 in of run, about 5 ft 8 in from the foot of the stringers to the header, and 2 ft 1 in across. A straight stair with 10 in treads needs 11 ft 8 in. An alternating tread stair at the same angle takes the same run; its gain is a deeper place to put each foot.

Two 2 × 12 stringers and 2 × 10 treads set ¾ in into dados, or on cleats, is the usual build: the 9¼ in tread meets the 8½ in tread-plus-nosing rule. The 9 ft example needs 12 ft stringers. An alternating stair adds a third stringer down the middle.

Long enough that you keep 6 ft 8 in of headroom above the nosings as you climb. Because the ladder is steep, that is short: about 4 ft 8 in for the 9 ft example at 60°, and the calculator gives yours. The width is the ladder plus its handrails.

A spiral needs a 5 ft square well but is a full stair that may be the main way up; a ship's ladder fits in about 2 ft by 6 ft but can be the only way up only to a loft of 200 sq ft or less without its own kitchen or bath. For anything bigger it can only be a second way up.

For your website

Run a contractor, supply or DIY site? Put this ship ladder and alternating tread stair calculator on your own page for free — it works the same as here and updates on its own.

Keep estimating