Attic insulation calculator

Attic insulation calculator:
bags of blown-in or batts by R-value

Insulation adds up by the inch. Tell the calculator what is in the attic now and what your zone calls for, and it turns the difference into inches, bags or batts.

Enter your attic

Area to insulate

Measure the attic floor, not the roof — or the wall or floor you are filling.

Insulation

Pebbly gray-brown or gold granules are vermiculite, which may contain asbestos. Do not disturb it, vacuum it or blow new insulation over it until it has been tested — the EPA advises leaving it alone and calling a trained professional.

Zone 1 is south Florida and Hawaii; 2 the Gulf Coast and Arizona; 3 the South and coastal California; 4 the mid-Atlantic and Pacific Northwest; 5 the lower Midwest and Northeast; 6 the upper Midwest and northern New England; 7 northern Minnesota and the Rockies. Figures are the 2021 code for new homes. From zone 4 north a wall needs R-20 in the cavity plus R-5 of foam board over the studs (or R-13 plus R-10), which means 2×6 framing; a 2×4 wall tops out at R-15. When topping up an attic that already has 3–4 inches, ENERGY STAR sets the bar one step lower — R-38 in zones 2–4, R-49 in 5–7. Changing the zone or the location sets the target; edit it if your code says otherwise.

Optional

What will it cost?

Every material the calculator worked out gets its own price. Each field starts at a typical US figure so you have something to work from — change any of them to what your own supplier charges.

These prices are approximate. They are national US retail figures, and what you actually pay varies with your region, your supplier, the season and how much you buy at once. Treat them as a starting point, not a quote — always price the job from your own supplier's current figures before you order.

Your prices

Safety glasses, a respirator and work gloves for handling insulation

Based on your result

What you'll need

Seal the attic floor first — the gaps around lights, pipes and the hatch leak more heat than thin insulation does — and keep the eave vents open with baffles before any loose fill goes in.

Insulation
Bags of blown-in or packages of batts at the R-value above
Calculate above
Rafter baffles
One per rafter bay at every vented soffit, keeping at least a 1 in air gap under the roof deck
—
Depth markers
Cardboard attic rulers stapled to the joists, one per 300 sq ft, to blow to the right depth
—
Air sealing
Fire-rated foam and caulk around every pipe, wire, light box and wall top plate — before any insulation goes in
first
Dams at the hatch and flues
Rigid boards around the attic hatch, sheet metal around flues and chimneys, taller than the finished depth
—
Respirator and goggles
An N95 or better, eye protection, long sleeves and gloves
1 set

Bags per 1,000 sq ft

Attic insulation calculator: bags of blown-in by R-value

Bags and finished depth for 1,000 square feet of bare attic floor, from the manufacturers' coverage charts. Over an existing layer you only blow the R you are adding — the calculator above does that subtraction.

Blown-inR-30R-38R-49R-60
Blown-in fiberglass (loose fill)
27.5 lb bag · R-2.9 per inch
15 bags
10.75 in
20 bags
13.5 in
25 bags
17 in
32 bags
20.5 in
Blown-in cellulose
19 lb bag · R-3.5 per inch
47 bags
9.6 in
61 bags
12 in
84 bags
15.2 in
108 bags
18.4 in

R-value per inch for every type, batt sizes and the zone map are on the insulation R-value chart guide.

The maths

How much insulation do I need?

The attic the calculator opens with is 40 by 30 feet, 1,200 square feet, with bare joists in zone 5, which calls for R-60. Blown fiberglass covers 31.3 sq ft per bag at that R, so the attic takes 39 bags, blown about 20.5 inches deep.

R to add = target R − existing R  (never below 0)
inches = R to add ÷ R per inch
bags = ⌈ area ÷ bag coverage at that R ⌉
packages = ⌈ area ÷ sq ft per package ⌉ × layers
  1. 01

    Measure the attic floor

    Length times width of the ceiling below, not the roof. A house footprint of 1,200 sq ft is a 1,200 sq ft attic floor.

  2. 02

    Seal, then read what is there

    Seal the gaps around pipes, wires and lights first — insulation slows heat, it does not stop air. Then push a ruler down to the drywall at a few spots and enter the depth and what the old layer is.

  3. 03

    Take the target from your zone

    R-30 in south Florida, R-49 across the South, R-60 from the mid-Atlantic north. Walls and floors have their own figures.

  4. 04

    Pick the material

    Blown-in fills around wires and framing and tops up an existing layer cleanly; batts suit open walls and floors. Cellulose packs more R per inch, fiberglass is lighter on the ceiling.

  5. 05

    Round up

    A short bag count leaves a cold corner. Home Depot lends the blower free with 10 bags; other stores set their own minimum.

Good to know

How this insulation calculator works, and other questions

20 bags of 27.5 lb blown fiberglass for R-38 and 25 for R-49 over bare joists; cellulose takes 61 and 84 of its 19 lb bags. Over an existing layer you need fewer — enter it above.

About 13.5 inches of blown fiberglass, or 12 inches of cellulose as blown, which settles to about 10.8. The bag chart gives the minimum depth for each R; blow to it everywhere, not just on average.

R-30 in zone 1, R-49 in zones 2–3 and R-60 in zones 4–7 under the 2021 code. Where an attic already has 3–4 inches, ENERGY STAR accepts one step lower. The zone table →

Yes, as long as the old layer is dry and not moldy. Blow loose fill over it or lay unfaced batts across the joists — never a second vapor-retarder face — and the R-values add.

Yes, at every rafter bay along the eaves where there are soffit vents. Without them loose fill drifts into the vents and the attic stops breathing, which leads to moisture and ice dams.

Only fixtures marked IC-rated (insulation contact). Older non-IC cans need about 3 in of clearance all round, or an airtight cover box over them, or they overheat. Check the label inside the fixture before blowing.

Keep it back by the clearance the flue maker and your code give — commonly 2 to 3 in for metal flues and chimneys — and fence that gap with sheet-metal dams taller than the finished depth. Fill the gap at the ceiling with high-temperature sealant, never with insulation.

Not over live knob-and-tube wiring: it was designed to shed heat into open air, so have an electrician check or replace it first. Pebbly gray-brown vermiculite may contain asbestos — leave it undisturbed and have it tested before any work.

Keep estimating